Physio Control Lifepak 15 User Manual

One moment please...
  1. Lifepak Defibrillator Operating Instructions
  2. Physio Control Lifepak 15 Price
  3. Physio Control Lifepak 15 Manual
  4. Physio Control Lifepak 15 Service Manual
  • Parts
DESCRIPTION

Help ensure the safety of your staff and patients. Only Physio-Control accessories and disposables have been thoroughly tested with Physio-Control products. We do not test Physio-Control equipment with any other manufacturer's electrodes, adapters or batteries, and we do not recommend using these products from sources other than Physio-Control. View and Download Medtronic LIFEPAK 20 service manual online. Page 5 PHYSIO-CONTROL, LIFEPAK. Keypad — The keypad is the primary user input control for the. Physio-Control Lifepak 12 Manuals / Documents. LifePak 12 Navigation Help. LifePak 12 Checklist. LifePak 12 Operating Instructions # 2. LifePak 12 Battery Support System 2 Service Manual. LifePak 12 Battery Support System 2 Checklist. LifePak 12 Battery Support System 2 Operating Instructions.

The multi-parameter LIFEPAK 12 defibrillator/monitor combines semi-automated and manual defibrillation.

The LIFEPAK 12 Defibrillator/Monitor is a multi-parameter device that combines semi-automated and manual defibrillation with capnography, external pacing, 12-lead electrocardiography and other monitoring functions. Its platform is upgradeable, allowing customers to add new parameters as their needs change and as new features are introduced.

FORUMSView All (47)
Ask a New Question

2

Replies
-MF_eng
3 months ago
3 months agoLP12 ECG Calibration Issue
During service activities I faced with ecg calibration issue with a Lifepak 12. Device creates 600d error code [ECG_ERROR_PREAMP_CALIBRATION] , and referring to special cable [3012087-00] and software [LP12ECG CAL]. I've got the cable, and the software from service manual cd as well. This cable is working, after ECG connected the LP12 start the calibration, and got data transfer as well (I can join to PC) by the way cable has two output, one for data transfer, one to ECG connector, and connects to PC with RS232 [COM1 port]. The problem is the this SW can't execute the calibration process, it just doesn't do anything. I can click to 'Start' after 'Continue' etc.. but it doesn't controls the LP12 calibraiton. Software can be find in service manual, page 265-266. Do you have any idea to solve the calibration?Reply
-Geneticmedcare
7 months ago
7 months agoBattery support System 2
My support battery from Lifepak12 gives me service error when I introduce the battery to charge it. Reply

3

Replies
-jason@elitebiomedical
8 months ago
8 months agoPower on and battery issue Battery Well#2
I have a LifePak 12 that will not recognize the battery and not power on with a battery in the Battery Well#2. The unit operates with a battery in Well#1. Anyone else had this issue? Reply
Physio Control Lifepak 15 User Manual
DOCUMENTS / MANUALSView All






VIDEOS

FEATURES

  • Compact and portable

  • Paddle preference - your choice of standard paddles, pediatric paddles, and/or sterilizable internal and external paddles

  • Compatible with QUIK-COMBO pacing/defibrillation/ECG electrodes

  • Easy, simple, and affordable upgrades

  • Guidance for compliance with HIPAA Security Standards for a Covered Entity available

    Operation Modes

  • Advisory Mode (SAS) - Provides all features available except manual defibrillation, synchronous cardioversion and pacing

  • Manual Mode - Provides normal operating capability for ALS users

  • Setup Mode - Allows operator to customize the device

  • Service Mode - Allows operator to execute device diagnostic tests and calibrations

  • Inservice Mode - Provides simulated waveforms for demonstration purposes

SPECIFICATIONS

Defibrillator TypeExternal, Automated (AED)
Height12.5 in
Length 9.1 in
Weight1.9 lbs
Width15.6 in
NEWSView All
Code STEMI Documentary Goes to London

Code STEMI is a web series that over the last year has been going to different cities to examine high-performing regional systems of care that have shown significant success improving heart attack and sudden cardiac arrest patient outcomes.

Device Alert

For complete details see web page http://www.physio-control.com/disclosure-and-safety.aspx Important Safety and Disclosure Information> Disclosures for Professional Users Online access to Operating Instructions is provided below for defibrillators and their...

LIFEPAK 15 Monitor/Defibrillator Operating Instructions
6.Encourage the patient to remain as still as possible.
12-LEAD.The 12-LEAD / AGE menu appears, prompting you to enter the patient’s age.
SPEED DIAL to select the age. Always enter the patient’s age if the patient is 15 years old
or younger. If you do not enter an age, the default value of 50 years is used by the interpretive
Physio control lp 15 manual

Lifepak Defibrillator Operating Instructions

analysis program and annotated on the 12-lead ECG report.
12-LEAD / SEX menu appears, prompting you to enter the patient’s sex.
SPEED DIAL to select the patient’s sex. If you do not enter the sex, the default of male is
used by the interpretive analysis program and is annotated on the 12-lead ECG report.
The monitor acquires, analyzes, and automatically prints the 12-lead ECG. An ECG leads-off
condition for any lead is indicated on the report by a dashed line.
Note: If 15 years or less is entered for patient age, the 12-lead ECG prints at diagnostic frequency
response of 0.05–150 Hz, even when 0.05–40 Hz is set up as the print default.
Note: When 12-LEAD is pressed, internal pacemaker detection is automatically enabled, even if the
ECG Override
If the monitor detects signal noise while acquiring data (such as patient motion or a disconnected
NOISY DATA! PRESS 12-LEAD TO ACCEPT. The message
remains and 12-lead ECG acquisition is interrupted until noise is eliminated. Take appropriate
action to eliminate the signal noise. This message remains as long as signal noise is detected.

Physio Control Lifepak 15 Price

When signal noise is eliminated, the monitor resumes acquiring data. To override the message and
acquire the 12-lead ECG in spite of the signal noise, press
acquired and printed with no interpretive statements. Any 12-lead ECG report acquired in this way
ECG OVERRIDE: DATA QUALITY PROHIBITS INTERPRETATION.
If the signal noise persists for longer than 30 seconds, 12-lead ECG acquisition stops. The screen
EXCESSIVE NOISE–12-LEAD CANCELLED. You must then press 12-LEAD to restart 12-lead ECG
Note: If 12-LEAD is pressed immediately after ECG electrodes are applied, the message NOISY DATA
may occur. This message is due to the temporary instability between the electrode gel and the

Physio Control Lifepak 15 Manual

patient’s skin that is not viewable on the ECG monitor screen, but is detected as noisy data. In
POSSIBLE INACCURATE DIAGNOSIS
If age and sex are not entered when a 12-lead ECG is obtained, the interpretive

Physio Control Lifepak 15 Service Manual

statements are based on a default of a 50-year-old male and may provide incorrect