ance since the last reset. This cost is calculated based on the total consumed
- Kill A Watt Ez P3 User Manual Beeping Generator
- Kill A Watt Ez P3 Manual
- Kill A Watt Ez P3
Page 3 Using the KILL A WATT P3 Plug the Kill A Watt into the wall, then plug the appliance into the socket on the front of the Kill A Watt. Next turn on the appliance or equipment. Suggestion: When monitoring a refrigerator or freezer, use an extension cord to position the “Kill A Watt”. Sep 19, 2014 P3 P4482 Kill A Watt Control, Calculates Electricity Costs & Carbon Footprint, Multi-event, 7-day, 24-hour Timer, Backlit Lcd Display, Displays Savings In Kwh, Dollars & Co2, Monitors Voltage, Amperage, Kwh & More, Ideal For Air Conditioners & Space Heaters.
Oct 20, 2009 This video describes how to use the Kill A Watt EZ and then determine the cost per year on different devices or appliances. UPDATED: 2-23-13 (the cost per kilowatt was accidentally set. P4400 Kill A W att TM Operation Manual Congratulations on your purchase of the Kill A W att Power Meter. Cared for properly, this unit will provide you with years of service. T h e L C D sh o ws a ll m e te r re a d in g s: V o lts, C u rre n t, W a tts, Fr e q u. Kill-A-Watt Monitor Instructions This Kill-A-Watt Monitor has been provided by Sustainable Energy Resource Group (802.785.4126, SERG@valley.net, ). The watt meters and energy library resources were donated by SERG thanks to a. Home Products Energy Savers P4460 Kill A Watt EZ. Empowers you to save $100's on electric bills! Now you can cut your energy costs and find out what appliances are actually worth keeping plugged in. Simply connect these appliances to the Kill A Watt® EZ, and it will assess how efficient they really are.
Kill A Watt Ez P3 User Manual Beeping Generator
power in KWH and the utility rate that you have set.
3. Don’t be surprised if the total cost display is 0.00 initially. It will take some time
4. Pressing the UP and DOWN key will cycle through the cost projection periods.
“Hour”, “Day”, “Week”, “Month”, and “Year” will display on the LCD to indicate
the selected period. The numeric display will indicate the projected cost to
run the attached appliance for the selected period. For example if the display
indicates $2.34 and “Month”, the unit is projecting that the attached appliance
will consume $2.34 worth of electricity at the programmed rate in one month.
5. These projections are based on real time and historical measurements of ac-
tual consumption of the attached appliance. The longer the appliance remains
attached to the unit, the more accurate the projection will be. This is especially
true for appliances that cycle on and off. Examples include refrigerators, televi-
sions, etc. Measurements conducted over long periods will accurately reect
true usage of the appliance. For example if a television is used 4 hours a day,
it is important to measure the 20 hours a day the appliance is not in use to get
6. For an appliance that cycles on and off, the projections cannot be accurate un-
til the unit has measured some full on and off cycles. Otherwise the projection
will be skewed. For example, if a connected television is powered on and you
reset the Kill A Watt™ EZ, the unit will begin measuring the power consump-
tion of a powered television. The only data available to the unit is power
consumption when the television is turned on. Initial projections of cost will
be high as the unit has not had the opportunity to measure power consump-
tion during the off cycle. If you observe the cost projection while the television
is turned off, you will see it decline over time. After the unit has been able to
measure several typical use cycles, the cost projections will settle to an ac-
7. For a device that is never turned off (e.g. a computer server) the cost projec-
tions will take less time to settle. You can observe accurate cost projections
within minutes. It is still best to let the unit measure power consumption over
an extended period. There can be power consumption variations even in
Measurement display:
1. To display the various available power measurements press the MENU key
until “Volt” is displayed on the LCD. In the Measurement display mode, the
Thank you for purchasing the P4460 Kill A Watt™ EZ Power Meter.
This operating manual will provide an overview of the product, safety
instructions, a quick guide to operation, and complete instructions for
correct usage. Take the time to completely review these instructions as
well as all safety warnings to ensure your best use of the product.
The P4460 Kill A Watt™ EZ is an easy to use consumer power meter
allowing the user to accurately measure power consumption of house-
hold appliances and to determine the actual cost of power consumed.
The unit will also project, in real time, the cost of continued use of the
appliance in time periods of Hour, Day, Week, Month, and Year. The
P4460 features a precise circuit which provides very accurate results.
Voltage and current are measured using true RMS methods. Total
consumed power is displayed in Kilowatt-hours (KWH). It is easy to
use with a large display and simple 5-button interface. The unit is safe
as it features ETL listing and over-current protection.
TM
P.F.
Elapsed Time
Total Year Month Week Day Hour
Volt Hz
Watt KWH
Kill A Watt Ez P3 Manual
Measurement Unit
Set Rate Key
AC Power Output
Time/Cost
Kill A Watt Ez P3
Menu Select Key