Atmor 301 Water Heater Manual User

  1. Atmor Water Heater Install
  2. Atmor Tankless Water Heater Manual
OPERATION INSTRUCTIONS
1. Your new Instant Water Heater is ow activated. Simply place one or both switches in the ON position

Atmor - Electric Instant Water Heaters The Smart Choice The atmor heater is built to supply endless flow of hot water on demand. By opening the control valve (tap) you activate the system, so that the flowing water is going through heating elements and come out to you at the desired temperature and flow rate. Oct 20, 2014 Atmor Super 900 Series Tankless Electric Water Heaters Paragon Group USA. Calefones electricos ATMOR linea 900. Installation and mounting of the mini instant water heater at a washbasin.

and turn on the hot water tap. You will need to allow at least 1.5 liters per minute to ow through the unit
in order to activate the Instant Heating System. Run water through the heater for a few minutes.
2. Be sure to every so often clean the spray head of sediment to assure a smooth water ow.
3. Be sure to every so often clean the incoming water lter.
4. The maximum operating water pressure is 8 atmospheres or 115 PSI. This is well above the usual 3
atmospheres or 40 PSI most municipal water systems provide.
Atmor
5. Be sure to install your Instant Water Heater in a heated location. It cannot be installed where temperatures
6. There are two ways to adjust the hot water temperature. One is by adjusting the ow, the other is by
changing the electrical settings on the unit. The slower the ow, the more time the unit has to heat the
water, resulting in higher water temperatures. Adding more rings to the water ow restrictor will limit the
ow and increase the output water temperature. You may choose the low, medium or high settings on
the heater, as required to achieve the water temperature desired.
Setting 0/OFF: No heating, lamp will not light. Setting 1: Low heating, lamp 1 will light.
Setting 2: Medium heating, lamp 2 will light. Setting 3: Maximum heating, both lamps will light.
For 220V - 240V 3.5kW unit only positions 0 & 1 are available.
7. During the summer, it is recommended using only setting 1 or 2 for device with 220V-240V 13kW output.
A. A separate electrical line is required.
B. The device must be connected to a separate circuit breaker.
C. The recommended electrical cable for feeding the device, see table I (next page).
and 220V-240V 3.5kW-8.6kW output
Device below a sink with 220V - 240V 8.6kW-10.6kW output
2. Thermal cut-out with reset
4. Relay
6. Switch 0- Off
7. Heating element
1. Terminal block
3. Thermal Cut out
5. Switch 0- Off
2- Medium
6. Heating element
8. EARTH(G) Connection in
41
1
536
L1
E(G)
E(G)

Atmor Water Heater Install

L1
L2

Atmor Tankless Water Heater Manual

N